# Nines Critical > Nines Critical is the mission-critical division of InfraredTeam (founded 1996, Dallas–Fort Worth, Texas). It provides Level III infrared thermography, PE-stamped arc flash studies and NFPA 70B electrical maintenance programs for data centers and mission-critical facilities across the United States. Inspections are performed on energized equipment under load, under the site's Method of Procedure (MOP), with no outage required. Key facts: - In data centers since 2009; data center and telecom work recorded every year since 2014. - More than 1 GW of data center design capacity scanned annually (published campus design capacity, including planned phases). - Across InfraredTeam since 1996: more than 10,000 inspections and an estimated 500,000+ components scanned, all facility types. - Thermographers have inspected sites in 45+ U.S. states. Every scan is led on site by a Level III certified thermographer. - Equipment scanned: medium- and low-voltage switchgear, transformers, ATS/STS, UPS modules and battery cabinets, PDUs/RPPs, overhead busway, generators and paralleling gear, and cooling equipment on request. - Reports list every inspected component, with thermal and visual images, temperature rise, a severity class from 1 (normal) to 4 (immediate action) and recommended actions. White-label reports for electrical contractor partners. - Recommended interval: full electrical scan annually (NFPA 70B-2026 maximum 12 months, Table 9.3.2), plus a mid-year scan of UPS, PDU, STS and busway. - UPS battery services: ohmic (impedance) testing of every jar, connection resistance, float voltage and ripple, capacity/load bank testing, preventive maintenance on the client's cadence, full string and individual jar replacement, battery monitoring installation, emergency replacement, removal and recycling with a certificate of recycling. VRLA, flooded wet cell, Ni-Cd and lithium-ion UPS batteries, nationwide. - Arc flash studies follow NFPA 70E (review at least every 5 years) and NEC 110.16 labeling. - Contact: info@ninescritical.com · https://www.ninescritical.com/contact/ ## Services - [Data center infrared thermography](https://www.ninescritical.com/services/data-center-infrared-thermography/): energized scans of the critical power path. - [Arc flash studies](https://www.ninescritical.com/services/arc-flash-studies/): short-circuit, coordination, incident energy, labels. - [NFPA 70B programs](https://www.ninescritical.com/services/nfpa-70b-maintenance-program/): twice-yearly critical-gear infrared, annual full scan, arc flash on cycle, one record. - [UPS battery services](https://www.ninescritical.com/services/ups-battery-services/): testing, maintenance, replacement, monitoring and recycling of data center UPS batteries. ## Company - [Proof and case studies](https://www.ninescritical.com/proof/) - [Partner program for electrical contractors](https://www.ninescritical.com/partners/) - [About](https://www.ninescritical.com/about/) - [FAQ](https://www.ninescritical.com/faq/) ## Guides - [How often does a data center need an infrared scan?](https://www.ninescritical.com/resources/nfpa-70b-infrared-frequency-data-centers/) - [Arc flash studies in data centers: what's required and when they expire](https://www.ninescritical.com/resources/arc-flash-study-data-center-requirements/) - [How often should data center UPS batteries be tested?](https://www.ninescritical.com/resources/ups-battery-testing-frequency-data-centers/)